ISSN 0430-6252. Physicochemical Mechanics of Materials. 2024.
Volume 60, Issue 2

Еlectrochemical behaviour of surface-modified commercially pure titanium in Ringer solution

Keywords

VT1-0 titanium, vacuum-arc spraying, thermodiffusion saturation, TiN coating, corrosion resistance, Ringer solution.

Cite as

Veselivska H. H., Proskurnyak R. V., Kuprin O. S., and Mashovets N. S. Еlectrochemical behaviour of surface-modified commercially pure titanium in Ringer solution. Physicochemical Mechanics of Materials. 2024. 60(2), 035-042.

https://doi.org/10.15407/pcmm2024.02.035

Abstract

The TiN coating obtained by vacuum-arc spraying on the surface of commercially pure VT1-0 titanium and thermodiffusion saturation in a nitrogen atmosphere was studied. The coatings were evaluated by electrochemical methods for determining their corrosion re­sistance in Ringer physiological solution. It was found that the TiN coating deposited on untreated titanium has twice lower corrosion current density of untreated titanium, while the nitrided surface, without and with the TiN coating, has a lower corrosion current den­sity by only 6 and 20% less, respectively. The TiN coating deposited on untreated titanium has the highest corrosion resistance, and the nitrided surface has the lowest corrosion re­sistance. Despite this ranking, the corrosion resistance of all investigated coatings is higher than that of the untreated VT1-0 titanium. Therefore, owing to the high electrochemical stability in Ringer solution, which contains Cl-ions, the simple surface modification tech­nology, and its non-toxicity, nitride coatings have a promising application in medicine.

References

  1. I. V. Okulov, H. Wendrock, A. S. Volegov, H. Attar, U. Kühn, W. Skrotzki, and J. Eckert, “High strength beta titanium alloys: new design approach,” Mater. Sci. and Eng.: A. 62, 297-302 (2015). https://doi.org/10.1016/j.msea.2015.01.073
  2. Q. Wang, Q. Li, X. Li, R. Zhang, X. Gao, C. Dong, and P. K. Liaw, “Microstructures and Stability Origins of β-(Ti,Zr)-(Mo,Sn)-Nb Alloys with Low Young’s Modulus,” Metallurgical and Mater. Transact. A: Physical Metallurgy and Mater. Sci., 46, Is. 9, 3924-3931 (2015). https://doi.org/10.1007/s11661-015-3011-4
  3. Kh. Shliakhetka, I. Pohrelyuk, H. Chumalo, R. Proskurnyak, S. Lavrys, and H. Veselivska, “Influence of concentration of sulfuric and hydrochloric acids on corrosion resistance of porous titanium,” J. of Mater. Sci., 58, P. 15047-15060 (2023). https://doi.org/10.1007/s10853-023-08964-9
  4. M. Niinomi, “Biologically and mechanically biocompatible titanium alloys,” Mater.Transact., 49, Is. 10, 2170-2178 (2008). https://doi.org/10.2320/matertrans.L-MRA2008828
  5. M. J., Runa, M. T., Mathew, and L. A. Rocha, “Tribocorrosion response of the Ti6Al4V alloys commonly used in femoral stems,” Tribology Int., 68, 85-93 (2013). https://doi.org/10.1016/j.triboint.2013.09.022
  6. A. Samanta, M. Bhattacharya, I. Ratha, H. Chakraborty, S. Datta, J. Ghosh, S. Bysakh, M. Sreemany, R. Rane, A. Joseph, S. Mukherjee, B. Kundu, M. Das, and A. K. Mukhopadhyay, “Nano- and micro-tribological behaviours of plasma nitrided Ti6Al4V alloys,” J. of the Mechanical Behavior of Biomedical Mater., 77, 267-294 (2018). https://doi.org/10.1016/j.jmbbm.2017.09.013
  7. E. Arslan, Y. Totik, and I. Efeoglu, “The investigation of the tribocorrosion properties of DLC coatings deposited on Ti6Al4V alloys by CFUBMS,” Progress in Organic Coatings, 74, Is. 4, 768-771 (2012). https://doi.org/10.1016/j.porgcoat.2011.10.023
  8. S. Wang, Y. Liu, C. Zhang, Z. Liao, and W. Liu, “The improvement of wettability, bio-tribological behavior and corrosion resistance of titanium alloy pretreated by thermal oxidation,” Tribology Int., 79, 174-182 (2014). https://doi.org/10.1016/j.triboint.2014.06.008
  9. J. Geringer, N. Demanget, and J. Pellier, “From acid etching treatments to tribocorrosive properties of dental implants: do some experimental results on surface treatments have an influence on the tribocorrosion behaviour of dental implants, J. of Physics D: Appl. Phys., 46, Is. 40 (2013). Article number 404005. https://doi.org/10.1088/0022-3727/46/40/404005
  10. M. Azz, and J. A. Szpunar, “Tribo-electrochemical technique for studying tribocorrosion behavior of biomaterials,” Biomolecular Eng., 24, Is. 5, 443-446 (2007). https://doi.org/10.1016/j.bioeng.2007.07.015
  11. M. Annunziata, A. Oliva, M. A. Basile, M. Giordano, N. Mazzola, A. Rizzo, A. Lanza, and L. Guida, “The effects of titanium nitride-coating on the topographic and biological features of TPS implant surfaces,” J. of Dentistry, 39, Is. 11, 720-728 (2011). https://doi.org/10.1016/j.jdent.2011.08.003
  12. S. Sathish, M. Geetha, N. D. Pandey, C. Richard, and R. Asoka, “Studies on the corrosion and wear behavior of the laser nitrided biomedical titanium and its alloys,” Mater. Sci. and Eng., 30, Is.3, 376-382 (2010). https://doi.org/10.1016/j.msec.2009.12.004
  13. A. Scarano, M. Piattelli, G. Vrespa, G. Petrone, G. Iezzi, and A. Piattelli, “Bone healing around titanium and titanium nitride-coated dental implants with three surfaces: an experimental study in rats,” Clinical Implant Dentistry and Related Res., 5, Is. 2, 103-111 (2003). https://doi.org/10.1111/j.1708-8208.2003.tb00191.x
  14. J. A. Hendry, and R. M. Pilliar, “The fretting corrosion resistance of PVD surface-modified orthopedic implant alloys,” J. of Biomedical Mater. Res., 58, 156-166 (2001). https://doi.org/10.1002/1097-4636(2001)58:2<156::AID-JBM1002>3.3.CO;2-8
  15. I. M. Pohrelyuk, O. V. Tkachuk, and R. V. Proskurnyak, “Corrosion resistance of the Ti-6Al-4V titanium alloy with nitride coatings in 0.9 % NaCl,” JOM, 63, Is. 6, 35-40 (2011). https://doi.org/10.1007/s11837-011-0090-6
  16. I. M. Pohrelyuk, J. Padgurskas, S. M. Lavrys, A. G. Luk’yanenko, V. S. Trush, and R. Kreivaitis, “Topography, hardness, elastic modulus and wear resistance of nitride coatings on titanium, “in: Proc. of 9th Int. Sci. Conf., BALTTRIB 2017, Kaunas (2017), pp. 41-46. https://doi.org/10.15544/balttrib.2017.09
  17. I. M. Pohrelyuk, O. V. Ovchynnykov, A. S. Skrebtsov, Kh. S. Shvachko, R. V. Proskurnyak, and S. M. Lavrys, “Corrosion properties of titanium obtained by the method of powder metallurgy,” Mater. Sci., 52, No. 5, 700-705 (2017). https://doi.org/10.1007/s11003-017-0012-z
  18. F. Seahjani, and H. Cimenoglu, “Nitriding of Cp titanium,” Defect and Diffusion Forum, 312-315, 1010-1014 (2011). https://doi.org/10.4028/www.scientific.net/DDF.312-315.1010
  19. J. Sun, Q. T. Yao, Y. H. Zhang, X. D. Du, Y. C. Wu, and W. P. Tong, “Simultaneously improving surface mechanical properties and in vitro biocompatibility of pure titanium via surface mechanical attrition treatment combined with low-temperature plasma nitriding,” Surf. Coat. Technol., 309, 382-389 (2017). https://doi.org/10.1016/j.surfcoat.2016.11.095
  20. D.-C., Sin, H.-L. Kei, and X. Miao, “Surface coatings for ventricular assist devices” Expert Review of Medical Devices, 6, Is. 1, 51-60 (2009). https://doi.org/10.1586/17434440.6.1.51
  21. I. Dion, C. Baquey, B. Candelon, and J. R. Monties, “Hemocompatibility of titanium nitride,” Int. J. of Artificial Organs., 15, Is. 10, 617-621 (1992). https://doi.org/10.1177/039139889201501009
  22. M. Schaldach, M. Hubmann, R. Hardt, and A. Weikl, “Titanium nitride cardiac pacemaker electrodes,” Biomedizinische Technik, 34, 185-190 (1989). https://doi.org/10.1515/bmte.1989.34.7-8.185
  23. S. F. Cogan, “Neural stimulation and recording electrodes, Annual Rev. of Biomedical Eng., 10, 275-309 (2008). https://doi.org/10.1146/annurev.bioeng.10.061807.160518
  24. P. R. Mezger, and N. H. J Creugers, “Titanium nitride coatings in clinical dentistry,” J. of Dentistry, 20, Is. 6, 342-344 (1992). https://doi.org/10.1016/0300-5712(92)90021-4
  25. Y. M. Ko, and H. C. Choe, “Effects of TiN film coating on the electrochemical behaviors of dental implant screw surface, Mater. Sci. Forum, 539-543, 726-730 (2007). https://doi.org/10.4028/www.scientific.net/MSF.539-543.726
  26. G. Faghani, S. M. Rabiee, S. Nourouzi, and H. Elmkhah, “Corrosion behavior of TiN/CrN nanoscale multi-layered coating in Ringer’s solution,” Int. J. of Eng. Transact. B: Applications, 33, Is. 2, 329-336 (2020). https://doi.org/10.5829/ije.2020.33.02b.18
  27. A. C. Ta, “The use of physiological solutions or media in calcium phosphate synthesis and processing, Acta Biomater., 10, 1771-1792 (2014). https://doi.org/10.1016/j.actbio.2013.12.047
  28. I. M. Pohrelyuk, S. E. Sheykin, S. M. Dub, A. G. Mamalis, I. Y. Rostotskii, O. V. Tkachuk, and S. M. Lavrys, “Increasing of functionality of c.p. titanium/UHMWPE tribo-pairs by thermodiffusion nitriding of titanium component,” Biotribology, 7, 38-45 (2016). https://doi.org/10.1016/j.biotri.2016.08.002
  29. H. H. Veselivska, I. M. Pkhrelyuk, R. V. Proskurnyak, and S. Kuprin, “Adhesion strength of TiN coating deposited on titanium with deifferent surface state,” Fizyko-Khmichna Mekhanika Materialiv, 59, No. 4, 89-94 (2023). https://doi.org/10.1007/s11003-024-00800-y
  30. V. P. Kolesnyk, O. М. Chuhai, D. V. Slyusar, O. S. Kalakhan, O. О. Voloshyn, S. V. Oleinyk, and H. H. Veselivs’ka, “Structure and properties of ionic-plasma WC coatings,” Mater. Sci., 55, No. 2, 214-218 (2019). https://doi.org/10.1007/s11003-019-00292-1
  31. V. F. Horban, I. V. Serdiuk, O. M. Chuhai, O. O. Voloshyn, S. V. Oliinyk, H. H. Veselivska, M. I. Danylenko, D. V. Sliusar, V. A. Stolbovyi, and O. S. Kalahan, “Specific features of the structure and electrophysical characteristics of nitride coatings based on Ti-V-Zr-Nb-Hf high-entropy alloy,” Mater. Sci., 57, No. 3, 428-433 (2021). https://doi.org/10.1007/s11003-021-00557-8
  32. A. S. Kuprin, S. A. Leonov, V. D. Ovcharenko, E. N. Reshetnyak, V. A. Belous, R. L. Vasilenko, G. N. Tolmachova, V. I. Kovalenko, and I. O. Klimenko, “Deposition of TiN-based coatings using vacuum arc plasma in increased negative substrate bias voltage, Problems of Atomic Sci. and Techn., 123, Is. 5, 154-160 (2009). https://doi.org/10.46813/2019-123-154
  33. K. Bouzid, N. E. Beliardouh, and C. Nouveau, “Wear and corrosion resistance of CrN-based coatings deposited by RF magnetron sputtering,” Tribology in Industry, 37, Is. 1, 60-65 (2015).
  34. R. A. Antunes, N. B. de Lima, M. de Almeida Rizzutto, O. Z. Higa, M. Saiki, and I. Costa, “Surface interactions of a W-DLC-coated biomedical AISI 316L stainless steel in physiological solution,” J. of Mater. Sci.: Materials in Medicine, 24, Is. 4, 863-876 (2013). https://doi.org/10.1007/s10856-013-4871-z
  35. B. Subramanian, C. V. Muraleedharan, R. Ananthakumar, and M. Jayachandran, “A comparative study of titanium nitride (TiN), titanium oxy nitride (TiON) and titanium aluminum nitride (TiAlN), as surface coatings for bio implants, Surf. and Coat. Technol., 205, Is. 21-22, 5014-5020 (2011). https://doi.org/10.1016/j.surfcoat.2011.05.004
  36. B. Gilberto, G. B. Maryory, O. A. Jaime, C. Á. Julio, and A. C. William, “Tribological properties and corrosion resistance enhancement of H13 hot work steel by means of CrN/TiN multilayers,” J. of Mater. Sci. and Eng., 4, Is. 6, 51-59 (2010).